MACOME
/6
LP-1903 Instructions (Ver. 001 /Sept. 18, 2009)
7-32-6 Nishikamata Ohta-ku Tokyo 1440051 Japan
Tel.:+81 3 3734 2211 Fax.:+81 3 3734 2217 http://www.macome.co.jp info@macome.co.jp
1
LP-1903 Long range positioning Sensor
INSTRUCTIONS
1. Summary
LP-1903 outputs an analog voltage which is proportionate to a
displacement from a center of a magnetic tape; SMG-100N
(ANALOG OUT) and Gate signal (GATE OUT) which signif ied that the
LP-1903 is on the guide tape.
OFF
ON
-3
-5
-7
3
5
7
0
-40±5
40±5
75mm~85mm
SMG-100N
Output voltage (V)
Displacement (mm)
at airgap 20mm
at airgap 30mm
at airgap 40mm
(at airgap 30mm)
Analog voltage OUT
GATE (Controllable area)
LP-1903
Traveling direction
2. Model No.
LP-1903-80; DC+12V power supply, Analog output area 80mm
LP-1903H-80; DC+24V power supply, Analog output area 80mm
MACOME
/6
LP-1903 Instructions (Ver. 001 /Sept. 18, 2009)
7-32-6 Nishikamata Ohta-ku Tokyo 1440051 Japan
Tel.:+81 3 3734 2211 Fax.:+81 3 3734 2217 http://www.macome.co.jp info@macome.co.jp
2
3. Specifications
Item Content
Power supply
DC+12V ±5% ripple 1% max. (LP-1903-80)
DC+24V ±5% ripple 1% max. (LP-1903H-80)
Power consumption 50mA max.
Operation temperature -10 to +50℃ (storage; -20 to +60℃)
Operation humidity
35% to 90%RH (non-condensing)
(storage;30% to 90%RH,non-condensing)
Operational Air gap 20 to 40mm (with SMG-100N)
Operational deviation ±5mm (from trucking direction center of SMG-100N)
Target Magnet SMG-100N
(North pole side of magnet should face to LP-1903.)
Insulation resistance DC500V 100MΩmin. (between case and power)
DC500V 100MΩ min. (between analog out and power)
I/O cord φ6 0.2mm2 1m
ANALOG OUT (Fig.1)
Voltage ±(5±1)V Insulated output (at air-gap 30mm)
Output impedance 2kΩ max.
Zero offset ±0.2V max.
Temp. drift 3mV/℃ (0V output point)
GATE OUT (Fig.2)
Area 75 to 85mm (at air-gap 30mm)
Output logic Normally open
Circuit NPN Transistor open collector
DC 30V max. sink current 100mA max
Fig.1 (ANALOG output)
0.047μF
510Ω
white
brown
Analog voltage OUT (-)
Analog voltage OUT (+)
MACOME
/6
LP-1903 Instructions (Ver. 001 /Sept. 18, 2009)
7-32-6 Nishikamata Ohta-ku Tokyo 1440051 Japan
Tel.:+81 3 3734 2211 Fax.:+81 3 3734 2217 http://www.macome.co.jp info@macome.co.jp
3
Fig.2 (GATE output)
blue
black
GATE OUT
4. Wiring
510Ω
0.047μF 0V
red
GATE OUT
blue Load
DC power
Analog voltage OUT (+)
white
Analog voltage OUT (-)
brown
black
DC+12V (LP-1903-80)
DC+24V (LP-1903H-80)
Apply diode when the load is inductive.
(rating 300V, 0.5A min.)
DC+30V max.
MACOME
/6
LP-1903 Instructions (Ver. 001 /Sept. 18, 2009)
7-32-6 Nishikamata Ohta-ku Tokyo 1440051 Japan
Tel.:+81 3 3734 2211 Fax.:+81 3 3734 2217 http://www.macome.co.jp info@macome.co.jp
4
5. Mounting
LP-1903 should keep distance from magnetism generators such as
motor. Vicinity of magnetic material causes LP-1903 inaccurate
output. In case of mounting LP-1903 on magnetic material, keep
distance from the material as follows. Use non-magnetic screws in
any case.
Correlation between LP-1903 and SMG-100N
50 100
±5
SMG-100N
Deviation
Traveling direction
LP-1903
20mm min.20mm min.
3
0m m m i n. 20mm min.20mm min.
MACOME
/6
LP-1903 Instructions (Ver. 001 /Sept. 18, 2009)
7-32-6 Nishikamata Ohta-ku Tokyo 1440051 Japan
Tel.:+81 3 3734 2211 Fax.:+81 3 3734 2217 http://www.macome.co.jp info@macome.co.jp
5
6. External Dimensions
100±0.5
5
0
0
.
5
1
0
0
0
+
1
0
0
14
6
5
0
5
0
2-C3
φ6 cord
60
2-φ5
soldered
(7)
1
100
5
0
Lot No.
Self-adhesive tape
Rubber magnet
Laminate (Color; Yellow)
SMG-100N
Upper Face; N-pole
97
7A
MACOME
/6
LP-1903 Instructions (Ver. 001 /Sept. 18, 2009)
7-32-6 Nishikamata Ohta-ku Tokyo 1440051 Japan
Tel.:+81 3 3734 2211 Fax.:+81 3 3734 2217 http://www.macome.co.jp info@macome.co.jp
6
7. Notices
(1) Avoid neither noise nor excessive surge on ANALOG OUT and GATE OUT.
(2) Strong tension or repeatable bending to input/output cord may cause
snapping of wires.
(3) Keep away from water since the housing is neither water nor splash proof.
Avoid dew-condensation.
(4) Keep away from solvent chemicals (acetone, thinner), since case or cord
may be deformed by those substances.
8. Warranty
Goods are warranted (exchange or repair) return to factory basis against
defects in workmanship and material for a period of one year from a date of
delivery.
The damage caused by following reasons is out of the warranty.
(1) Inappropriate installation and usage.
(2) Abnormal effect from peripheral equipment.
(3) Alternation or repair without us.
(4) Force majeure.
The Induced damage is out of the warranty.
9. Range of service
Prices on the price list are not including following fees. Consult us for the fees.
(1) Adjustment, instruction and presence at installation.
(2) Maintenance and repair.
(3) Technical advice and training.
* Specifications are subject to change without notice. *

PDF Document reader online

This website is focused on providing document in readable format, online without need to install any type of software on your computer. If you are using thin client, or are not allowed to install document reader of particular type, this application may come in hand for you. Simply upload your document, and Docureader.top will transform it into readable format in a few seconds. Why choose Docureader.top?

  1. Unlimited sharing - you can upload document of any size. If we are able to convert it into readable format, you have it here - saved for later or immediate reading
  2. Cross-platform - no compromised when reading your document. We support most of modern browers without the need of installing any of external plugins. If your device can oper a browser - then you can read any document on it
  3. Simple uploading - no need to register. Just enter your email, title of document and select the file, we do the rest. Once the document is ready for you, you will receive automatic email from us.

Previous 10

Next 10